What is DIN 18202?

Figure 6 Position Deviations and Distances Between Measuring Points In A Check for Flatness (e.g. using a straightedge and wedge)

What is DIN 18202?

A DIN standard is a standard drawn up at the German Institute for Standardization (DIN)

  • DIN 18202 superseded DIN 1801.
  • It was revised and released as DIN 18202 in April of 1997

It has not been updated since.

  • The standard applies to building tolerances in general, however, the section applicable to floor flatness (Section 5) uses a form of a GUSE or “Gap Under Straight Edge” standard.

Gap Under Straight Edge

There are many forms of Gap Under Straight Edge (GUSE), the DIN18202 uses the following:

DIN 18202 Flatness Tolerance Table

Rules of DIN 18202

Flatness Tolerances

  • Table 3 gives position deviations in the form of permitted flatness tolerances, applicable to the surfaces of floors, ceilings, screed, floorings, and walls irrespective of their position.
  • They shall not apply to sprayed concrete surfaces.
  • If the flatness of surfaces is to be subject to more stringent requirements (cf. lines 2, 4, and 7 of table 3), this shall be agreed on in the bill of quantities.
  • Where the depth of masonry is equal to the thickness of a brick, the flatness tolerances shall only apply to the fair face.
  • Where walls, floors, ceilings, screed, and floorings have finished surfaces, jogs shall be avoided except where such features are part of the design.
  • Jogs between adjacent components shall be dealt with separately
  • The permitted deviations from flatness for construction materials shall be taken into account separately as they are not included in the flatness tolerances specified here.

Permitted Deviation for DIN 18202

The only other applicable parts of DIN 18202 to a flooring contractor or floor flatness test company, or consultant are Table 1 Group 2, which specifies the dimensions in elevation limits.

Application of DIN 18202

There is no specification for the number of tests on the floor.

The tests can be laid out randomly or in a grid pattern that must be tied to a reference plane.

Real World DIN 18202

As a GUSE standard, DIN 18202 is inherently subjective.

Thus, the questions one needs to ask as either a contractor or a test agency with a DIN 18202 standard up front:

  1. How do I find the highest and lowest point?
  2. Whose level do I use?
  3. How do I determine which direction to point the level?
  4. Since it is usually random, how many tests do I perform? (Common practice is to use the Divide by 10 rule.)
  5. How do I use this to accomplish the design intent on a project?

www.axiom1155.com

www.someromatsongroup.com

References:

DIN 18202 Tolerances in building construction – Buildings April of 1997

https://www.en-standard.eu/din-18202-tolerances-in-building-construction-buildings/?srsltid=AfmBOorG4IZHB8T1fO-Z_nZRYTm5QdK2wyPI7Wzuy38sWNlq2ua7ThdK
/ THE AXIOM 1155

Measure it yourself, to the standard.

The Axiom 1155 walking floor profiler measures floor profiles and joint deflection to ASTM E1155 and TR34, straight from a Bluetooth enabled Android device. Questions about pricing, training, or certification? Our team is a call away.

/ KEEP READING

Related articles

Secret Link
×
Your Cart
Cart is empty.
Fill your cart with amazing items
Shop Now
$0.00
Shipping & taxes may be re-calculated at checkout
$0.00